Skip to content

Tubular Heat Exchanger

Innohx sterile double tube plate heat exchangers currently include TU series (U-tube), TDU series (straight tube double process), TDC (suction straight tube single process), TDM series (micro sterile), etc.

  • Design of straight pipes (standard including corrugated pipes) and U-shaped pipes
  • Can be designed for horizontal or vertical installation
  • Single process, dual process, and multi process design
  • Sterile double tube plate design, completely separating the tube and shell sides to prevent cross contamination
  • The slope of the heat exchange tube bundle ensures a fully drained design
  • The baffle design ensures the clean discharge of shell side media
  • Designed according to ASME BPE and TEMA standards, in compliance with cGMP and FDA specifications
  • The inner surface can be electropolished to ensure smooth and consistent inner walls
  • CNC machining ensures the accuracy and consistency of products
  • Each heat exchanger has been cleaned and passivated before leaving the factory
  • 304SS insulation outer layer can be added
  • Endoscopic examination
  • Hydrostatic testing
  • X-ray analysis
  • Performance simulation test of working conditions
  • Computer Performance Simulation
  • Customize simulation and testing according to customer requirements
  • Heating and cooling of injection water (WFI) and pure water (PW)
  • Heating and cooling of sterile fluids
  • Pure steam condensation
  • Heating and cooling of the CIP process
  • Pure steam sampling
  • Welding records available
  • Passivation and polishing documents
  • Welding records available
  • Material Chemical Composition Report
  • Elastomer provides FDA report
  • Complete selection calculation sheet
  • Temperature range: -10 ℃ -160 ℃, optional 200 ° C
  • Standard design pressure: 10bar (optional 16bar)
  • Standard shell side maximum flow rate: 45m ³/ Hr
  • Tube diameter: standard 316L, optional 904L or other alloys
  • Shell pass: standard 304SS
  • Standard mechanical polishing to 0.4um, optional electric polishing
  • Standard model heat exchanger area: maximum 8.5 square meters
  • Non standard models are designed and manufactured based on selection
ModelTube OD
mm
Shell OD
mm
L1
mm
L2
mm
L3
mm
L4
mm
TU0040-19.53101.68001250200870
TU0070-19.53114.38001250200870
TU0080-19.53141.38001250225870
TU0120-112.7168.38001250225870
TU0250-112.7219.18001250240870
TU0100-29.53101.580022502001870
TU0180-29.53114.380022502251870
TU0190-29.53141.3180022502001870
TU0260-212.7168.3180022502251870
TU0550-212.7219.1180022502401870
TU0160-39.53101.6180032502002870
TU0280-39.53144.3280032502002870
TU0310-39.53114.36280032502252870
TU0400-312.7168.3280032502252870
TU0850-312.7219.1280032502402870
ModelTube OD
mm
Shell OD
mm
L1
mm
L2
mm
L3
mm
L4
mm
TDU0013-19.537310001150180810
TDU0038-19.5388.910001150180810
TDU0063-19.53101.610001150180810
TDU0076-19.53114.310001150180810
TDU0110-19.53141.310001150180810
TDU0180-112.7168.310001150200810
TDU0320-112.7219.110001150200810
ModelTube OD
mm
Shell OD
mm
L1
mm
L2
mm
L3
mm
L4
mm
TDC0020-19.537310001150180810
TDC0050-19.5388.910001150180810
TDU0063-19.53101.610001150180810
TDC0080-19.53114.310001150180810
TDC0090-19.53141.310001150180810
TDC0130-19.53141.310001150200810
TDC0200-112.7168.310001150200810
TDC0350-112.7219.110001150200810